Vector HE

Kody Alarmowe Carrier Transicold

Vector HE

Alarm number Unit Concerned Description ALARM ONLY? UNIT SHUTDOWN?
1 ST & MT LOW FUEL LEVEL WARNING ALARM ONLY
11 ST & MT CHECK ENGINE OIL PRESSURE SHUTDOWN
12 ST & MT HIGH COOLANT TEMPERATURE SHUTDOWN
13 ST & MT HIGH DISCHARGE PRESSURE SHUTDOWN
14 ST & MT HIGH A/C AMPS SHUTDOWN
15 ST & MT BATTERY VOLTAGE TOO HIGH SHUTDOWN
16 ST & MT BATTERY VOLTAGE TOO LOW SHUTDOWN
17 ST & MT HIGH COMP DISCHARGE TEMP SHUTDOWN
18 ST & MT LOW REFRIGERANT PRESSURE SHUTDOWN
19 ST & MT LOW FUEL SHUTDOWN SHUTDOWN
20 ST & MT MAXIMUM COMPRESSOR ALARMS SHUTDOWN
21 ST & MT TECHNICIAN RESET REQUIRED SHUTDOWN
22 ST & MT LOW SUCTION SUPERHEAT SHUTDOWN
23 ST & MT A/C CURRENT OVER LIMIT SHUTDOWN
24 ST & MT COMPRESSION RATIO EXCEEDED SHUTDOWN
27 ST & MT HIGH SUCTION PRESSURE SHUTDOWN
28 ST & MT CHECK REFRIGERATION SYSTEM SHUTDOWN
30 ST & MT FAILED TO RUN MINIMUM TIME SHUTDOWN
31 ST & MT FAILED TO START – AUTO MODE SHUTDOWN
34 ST & MT ENGINE FAILED TO STOP ALARM ONLY
35 ST & MT CHECK STARTER CIRCUIT SHUTDOWN
36 ST & MT CHECK COOLANT TEMPERATURE ALARM ONLY
37 ST & MT CHECK LOW SPEED RPM ALARM ONLY
38 ST & MT CHECK HIGH SPEED RPM ALARM ONLY
39 ST & MT CHECK ENGINE RPM SHUTDOWN if configured YES
40 ST & MT CHECK ENGINE PREHEAT CIRCUIT ALARM ONLY
41 ST & MT ENGINE STALLED SHUTDOWN
51 ST & MT ALTERNATOR (BATTERY CHARGER) NOT CHARGING SHUTDOWN
53 ST & MT BOX TEMP OUT-OF-RANGE SHUTDOWN if configured YES
54 ST & MT DEFROST NOT COMPLETE ALARM ONLY
55 ST & MT CHECK DEFROST AIR SWITCH ALARM ONLY
57 ST & MT REMOTE SWITCH (REMS1) SHUTDOWN if configured YES
58 ST & MT REMOTE SWITCH (REMS2) SHUTDOWN if configured YES
59 ST & MT DATALOGGER (DataLink data recorder) NOT RECORDING ALARM ONLY
60 ST & MT REAL TIME CLOCK FAIL ALARM ONLY
61 ST & MT DOOR OPEN ALARM ONLY
62 ST & MT C2 BOX TEMP OUT-OF-RANGE ALARM ONLY
63 ST & MT C3 BOX TEMP OUT-OF-RANGE ALARM ONLY
66 ST & MT CHECK EVAP SENSOR GROUP ALARM ONLY
73 ST & MT NO POWER-CHECK POWER CORD SHUTDOWN
74 ST & MT PHASE REVERSED SHUTDOWN
75 ST & MT COMP MOTOR OVERLOAD SHUTDOWN
76 ST & MT CONDENSER MOTOR OVERHEATED SHUTDOWN
77 ST & MT EVAP MOTOR OVERHEATED SHUTDOWN
81 ST & MT CHECK FUEL HEATER RELAY ALARM ONLY
84 ST & MT CHECK REMOTE ALARM LIGHT ALARM ONLY
91 ST & MT CHECK HEATER 1 ALARM ONLY
92 ST & MT CHECK HEATER 2 ALARM ONLY
93 ST & MT CHECK STARTUP BUZZER ALARM ONLY
94 ST & MT CHECK COMP CONTACTOR 1 SHUTDOWN
95 ST & MT CHECK CDCON1 COIL ALARM ONLY
96 ST & MT CHECK GENCOIL COIL SHUTDOWN
98 ST & MT CHECK HIGH TEMP THERMOSTAT ALARM ONLY (SHUTDOWN HEATERS)
100 ST & MT OVERLOAD/GROUND FAULT SHUTDOWN
101 MT only C2 EVAP MOTOR OVERHEATED SHUTDOWN CPT 2 ONY
102 MT only C3 EVAP MOTOR OVERHEATED SHUTDWON CPT 3 ONLY
103 MT only CHECK 2HTCON1 COIL ALARM ONLY
104 MT only CHECK 2HTCON2 COIL ALARM ONLY
105 MT only CHECK 3HTCON1 COIL ALARM ONLY
106 MT only CHECK 3HTCON2 COIL ALARM ONLY
109 ST & MT CHECK 1EVCON COIL ALARM ONLY
110 MT only CHECK 2EVCON COIL ALARM ONLY
111 MT only CHECK 3EVCON COIL ALARM ONLY
114 ST & MT CHECK LIV CIRCUIT ALARM ONLY
121 ST & MT CHECK AMBIENT AIR SENSOR ALARM ONLY
122 ST & MT CHECK RETURN AIR SENSOR ALARM ONLY
123 ST & MT CHECK SUPPLY AIR SENSOR
124 ST & MT CHECK DEFROST TERM 1 SENSOR ALARM ONLY
125 ST & MT CHECK COMP DISCHARGE SENSOR ALARM ONLY
126 ST & MT CHECK FUEL SENSOR CIRCUIT ALARM ONLY
127 ST & MT CHECK SUCTION TEMP SENSOR ALARM ONLY
128 ST & MT LOW/UNBALANCED A/C AMPS SHUTDOWN
129 ST & MT CHECK ENG COOLANT SENSOR ALARM ONLY
130 ST & MT CHECK ENGINE RPM SENSOR ALARM ONLY
131 ST & MT CHECK EVAP TEMP SENSOR ALARM ONLY
133 ST & MT CHECK REMOTE TEMP SENSOR 1 ALARM ONLY
134 ST & MT CHECK REMOTE TEMP SENSOR 2 ALARM ONLY
135 ST & MT CHECK REMOTE TEMP SENSOR 3 ALARM ONLY
136 MT only C2 CHECK SUPPLY AIR SENSOR ALARM ONLY
137 MT only C2 CHECK RETURN AIR SENSOR ALARM ONLY
138 MT only C3 CHECK RETURN AIR SENSOR ALARM ONLY
139 MT only C2 CHECK DEFROST TERM 1 SENSOR ALARM ONLY
140 MT only C3 CHECK DEFROST TERM 1 SENSOR ALARM ONLY
P00141 ST & MT PRETRIP STOPPED BY USER ALARM ONLY
P00146 MT only C2 CHECK HEATER 1 CIRCUIT ALARM ONLY
P00147 MT only C2 CHECK HEATER 2 CIRCUIT ALARM ONLY
P00151 ST & MT CHECK GLOW CIRCUIT (This applies to the engine preheater = EPH) ALARM ONLY
P00153 ST & MT CHECK RETURN AIR SENSOR ALARM ONLY
P00154 ST & MT CHECK SUPPLY AIR SENSOR ALARM ONLY
P00155 ST & MT CHECK COOLANT TEMP SENSOR ALARM ONLY
P00157 ST & MT CHECK BATTERY CURRENT ALARM ONLY
P00158 ST & MT CHECK AMBIENT AIR SENSOR ALARM ONLY
P00159 ST & MT CHECK DEFROST TERM 1 SENSOR ALARM ONLY
P00160 ST & MT CHECK DISCHARGE TEMP SENSOR ALARM ONLY
P00161 ST & MT CHECK SUCTION TEMP SENSOR ALARM ONLY
P00163 MT only C3 CHECK HEATER 1 CIRCUIT ALARM ONLY
P00166 MT only C2 CHECK SUPPLY AIR SENSOR ALARM ONLY
P00167 MT only C3 CHECK HEATER 2 CIRCUIT ALARM ONLY
P00170 ST & MT CHECK LIV CIRCUIT ALARM ONLY
P00173 ST & MT CHECK ECONOMIZER ALARM ONLY
P00174 ST & MT CHECK LOW SPEED RPM ALARM ONLY
P00175 ST & MT CHECK HIGH SPEED RPM ALARM ONLY
P00177 ST & MT CHECK EXV (EVXV) SUPERHEAT ALARM ONLY
P00179 ST & MT CHECK LIV ALARM ONLY
P00180 ST & MT CHECK SUCTION MOD VALVE ALARM ONLY
P00184 MT only C2 CHECK EVAPORATOR FAN MOTOR ALARM ONLY
P00185 MT only C3 CHECK EVAPORATOR FAN MOTOR ALARM ONLY
P00186 ST & MT CHECK EVAP OUTLET TEMP ALARM ONLY
P00187 ST & MT CHECK HEATER 1 CIRCUIT ALARM ONLY
P00188 ST & MT CHECK HEATER 2 CIRCUIT ALARM ONLY
P00189 ST & MT CHECK EVAPORATOR FAN MOTOR ALARM ONLY
P00190 ST & MT CHECK CONDENSER FAN MOTOR ALARM ONLY
P00199 MT only C2 CHECK RETURN AIR SENSOR ALARM ONLY
P00206 ST & MT CHECK CONDENSER FAN CIRCUIT ALARM ONLY
P00207 ST & MT CHECK COMPRESSOR CONTACT CIRCUIT ALARM ONLY
P00208 ST & MT CHECK GENERATOR CONTACT CIRC ALARM ONLY
P00209 ST & MT CHECK STANDBY CONT CIRCUIT ALARM ONLY
P00210 MT only C3 CHECK RETURN AIR SENSOR ALARM ONLY
P00211 MT only C2 CHECK DEFROST SENSOR ALARM ONLY
P00212 MT only C3 CHECK DEFROST SENSOR ALARM ONLY
223 ST & MT ENGINE MAINTENANCE DUE ALARM ONLY
224 ST & MT STANDBY MAINTENANCE DUE ALARM ONLY
225 ST & MT GENERAL MAINTENANCE DUE ALARM ONLY
226 ST & MT SERVICE SOON-PM #1 DUE ALARM ONLY
227 ST & MT SERVICE SOON-PM #2 DUE ALARM ONLY
228 ST & MT SERVICE SOON-PM #3 DUE ALARM ONLY
229 ST & MT SERVICE SOON-PM #4 DUE ALARM ONLY
230 ST & MT SERVICE SOON-PM #5 DUE ALARM ONLY
232 ST & MT SETPOINT ERROR SHUTDOWN
233 ST & MT MODEL # ERROR SHUTDOWN
237 ST & MT FUNCTION PARAMETERS ERROR SHUTDOWN
238 ST & MT CONFIGURATIONS ERROR SHUTDOWN
245 ST & MT CANNOT SAVE SETTING ALARM ONLY
246 ST & MT EEPROM WRITE FAILURE SHUTDOWN
248 ST & MT CONFIG MODE / HP2 ERROR SHUTDOWN
255 ST & MT MICROPROCESSOR ERROR SHUTDOWN
2000 ST & MT UPDATE SOFTWARE SHUTDOWN
2001 ST & MT REAR PANEL SHUTDOWN SHUTDOWN
2003 ST & MT DISPLAY MODULE ERROR SHUTDOWN
2006 ST & MT STARTER OUTPUT FAULT SHUTDOWN
4000 ST & MT REMOTE SWITCH (REMS3) ALARM ONLY
4002 ST & MT HIGH ECONOMIZER SUPERHEAT ALARM ONLY
4004 ST & MT NO SETPOINT CHANGE ALARM ONLY
4005 MT only NO SETPOINT CHANGE C2 ALARM ONLY
4006 MT only NO SETPOINT CHANGE C3 ALARM ONLY
4007 MT only CHECK C2 CONFIGURATION ALARM ONLY
4008 MT only CHECK C3 CONFIGURATION ALARM ONLY
5005 ST & MT BAD F9 FUSE SHUTDOWN
5006 ST & MT POWER ENABLE RELAY FUSE ALARM SHUTDOWN
5007 ST only STEPPER BOARD FUSE ALARM ALARM ONLY
5009 ST & MT CHECK STANDBY CONTACTOR ONE (PSCON) SHUTDOWN
5010 ST & MT CHECK STANDBY CONTACTOR TWO (PSCON2) SHUTDOWN
5012 ST & MT CHECK ENCU POWER CIRCUIT ALARM ONLY
5014 ST & MT CHECK STARTER SOLENOID CIRCUIT ALARM ONLY
5016 ST & MT CHECK REMOTE AMBER LIGHT ALARM ONLY
5017 ST & MT CHECK ENG PREHEAT ENABLE CIRCUIT ALARM ONLY
5018 ST & MT CHECK POWER ENABLE CONTROL ALARM ONLY
5019 ST & MT CHECK CDCON2 COIL ALARM ONLY
5020 ST & MT CHECK HTCON1 ALARM ONLY
5021 ST & MT CHECK HTCON2 ALARM ONLY
5022 MT only C2 CHECK HIGH TEMP THERMOSTAT ALARM ONLY
5023 MT only C3 CHECK HIGH TEMP THERMOSTAT ALARM ONLY
5028 ST & MT PM FUSE 2 ALARM SHUTDOWN
5029 ST & MT PM FUSE 3/5/7 ALARM ALARM ONLY
5030 ST & MT PM FUSE 4 ALARM SHUTDOWN
5031 ST & MT PM FUSE 10 ALARM SHUTDOWN
5032 ST & MT PM FUSE 11 ALARM SHUTDOWN
5033 ST & MT POWER ENABLE COIL OPEN CIRCUIT SHUTDOWN
5034 ST & MT POWER ENABLE CONTACT FAIL ALARM SHUTDOWN
5035 ST & MT EVXV FAULT ALARM ONLY
5036 ST & MT ECXV FAULT ALARM ONLY
5037 ST & MT SMV FAULT ALARM ONLY
6000 ST & MT CONDENSER MOTOR2 OVERHEATED SHUTDOWN
6001 ST & MT CHECK LIGHT BAR ALARM ONLY
6006 MT only DRAIN HEAT 2 ALARM ONLY
6007 MT only DRAIN HEAT 3 ALARM ONLY
7000 ST & MT ECONOMIZER TEMP SENSOR ALARM ONLY
7002 MT only C3 CHECK SUPPLY AIR SENSOR ALARM ONLY
7003 MT only C2 CHECK EVAC TEMP SENSOR ALARM ONLY
7004 MT only C3 CHECK EVAC TEMP SENSOR ALARM ONLY
7006 ST & MT SUCTION PRESSURE SENSOR ALARM ONLY
7008 ST & MT CHECK REDUNDANT RETURN AIR SENSOR (RAT2) ALARM ONLY
7009 ST & MT RETURN AIR SENSORS OUT OF RANGE (RAT & RAT2) ALARM ONLY
7011 ST & MT EVAP PRESS SENSOR AlARM ONLY
7012 ST & MT ECONOMIZER PRESS SENSOR AlARM ONLY
7013 ST & MT DISCHARGER PRESS SENSOR AlARM ONLY
P11000 ST & MT CHECK CONDENSER FAN MOTOR 2 ALARM ONLY
P11005 MT only CHECK DRAIN HEATER 2 ALARM ONLY
P11006 MT only CHECK DRAIN HEATER 3 ALARM ONLY
P12000 MT only C3 CHECK AIR SUPPLY SENSOR ALARM ONLY
P12001 MT only C2 CHECK EVAP OUTLET TEMP ALARM ONLY
P12002 MT only C3 CHECK EVAP OUTLET TEMP ALARM ONLY
P12003 ST & MT CHECK ECONOMISER SENSOR TEMP ALARM ONLY
P13000 ST & MT CHECK CONDENSER FAN 2 CIRCUIT ALARM ONLY
P14000 MT only C2 CHECK EVAP1 SUPERHEAT ALARM ONLY
P14002 MT only C3 CHECK EVAP1 SUPERHEAT ALARM ONLY
21100 ST & MT NO COMM FROM ANY BOARD TO MAIN MICRO SHUTDOWN
22100 MT only INPUT BOARD1 (ON SIM) – CAN FAIL SHUTDOWN
22101 MT only INPUT BOARD1 (ON SIM) – LOW SENSOR VOLTAGE ALARM ONLY
22102 MT only INPUT BOARD1 (ON SIM) – HIGH SENSOR VOLTAGE ALARM ONLY
22103 MT only INPUT BOARD1 (ON SIM) – LOST CONFIGURATION SHUTDOWN
22800 ST & MT MCA-IN – CAN FAIL SHUTDOWN
22801 ST & MT MCA-IN – LOW SENSOR VOLTAGE ALARM ONLY
22802 ST & MT MCA-IN – HIGH SENSOR VOLTAGE ALARM ONLY
22803 ST & MT MCA-IN – LOST CONFIGURATION SHUTDOWN
23800 ST & MT PM – CAN FAIL SHUTDOWN
23803 ST & MT PM LOST CONFIGURATION SHUTDOWN
24100 ST & MT NO COMM FROM MICRO TO CCB SHUTDOWN
24101 ST & MT SENSOR INPUT VOLTAGE LOW CCB ALARM ONLY
24102 ST & MT SENSOR INPUT VOLTAGE HIGH CCB ALARM ONLY
24103 ST & MT LOST CONFIGURATION CCB SHUTDOWN
25100 ST ony NO COMM FROM MICRO TO SVM SHUTDOWN
25101 ST ony OVER CURRENT SVM ALARM ONLY
25102 ST ony CHECK INPUT VOLTAGE SVM ALARM ONLY
25500 MT only SIM – CAN FAIL SHUTDOWN
25501 MT only SIM OVER CURRENT ALARM ONLY
25502 MT only SIM INPUT VOLTAGE ALARM ONLY
25503 MT only SIM LOST CONFIGURATION VOLTAGE SHUTDOWN
25800 ST & MT SIO – CAN FAIL SHUTDOWN
25801 ST & MT SIO OVER CURRENT ALARM ONLY
25802 ST & MT SIO INPUT VOLTAGE ALARM ONLY
25803 ST & MT SIO LOST CONFIGURATION VOLTAGE SHUTDOWN
26100 ST & MT NO COMM FROM MICRO TO ENCU SHUTDOWN
26301 ST & MT ENGINE SHUTDOWN ALARM (RED – CHECK ENGINE IMMEDIATELY) SHUTDOWN
26302 ST & MT ENGINE WARNING ALARM (RED – CHECK ENGINE IMMEDIATELY) ALARM ONLY
26500 ST & MT INCOMPATIBLE ENCU SHUTDOWN
27200 ST & MT NO COMM FROM MICRO TO OPTIONAL COMM MODULE ALARM ONLY
28001 ST & MT NO COMM FROM FUEL SENSOR ALARM ONLY
28002 ST & MT NO COMM FROM DOOR SWITCH ALARM ONLY
28003 ST & MT INVALID DOOR SWITCH ALARM ONLY
28004 ST & MT INVALID REMS1 ALARM ONLY
28005 ST & MT INVALID REMS2 ALARM ONLY
28006 ST & MT INVALID REMS3 ALARM ONLY
28007 ST & MT INVALID REMS4 ALARM ONLY
28008 ST & MT NO COMMUNICATION FROM FUEL FLOW METER ALARM ONLY
0 +
Firm współpracujących

Opracowywanie innowacyjnych rozwiązań dotyczących łańcucha chłodniczego jest głęboko zakorzenione w kulturze firmy Carrier Transicold, gdzie przestrzeganie zasad zachowania ciągłości łańcucha chłodniczego ma kluczowe znacznie dla zapewnienia optymalnych warunków dostawy łatwo psujących się, świeżych i mrożonych towarów do klientów.

E-DRIVE® - WYPRÓBOWANA TECHNOLOGIA OD 1999 R.

Całkowicie elektryczna technologia E-Drive® eliminuje mechaniczne przekazywanie napędu stosowane w układach z napędem paskowym i przekształca mechaniczną energię silnika w energię elektryczną.

To unikalne i opatentowane rozwiązanie zapewnia znakomitą wydajność łańcucha chłodniczego, zmniejszając emisję CO2 i całkowite koszty eksploatacji.

  • Sprawność eksploatacyjna sięgająca 99,4%
  • Dokładność utrzymywania temperatury łańcucha chłodniczego +/-0,8°C
  • Zmniejszona emisja dwutlenku węgla

AdvanTE3C - Innowacyjność ukierunkowana na klienta

Zasadniczą sprawą dla naszych klientów jest optymalny transport ich produktów i dostarczanie tych produktów przy zachowaniu najlepszej jakości. Centrum Rozwiązań AdvanTE³C to ogólnoświatowa grupa ekspertów w dziedzinie wydajności i środowiska naturalnego, skupiająca się na opracowywaniu rozwiązań transportowych nieszkodliwych dla środowiska.

Prowadzone przez nich badania doprowadzą w przyszłości do wdrożenia nowych technologii, prowadzących do przedefiniowania łańcucha chłodniczego.

Rien_Boom_trucks

COMPANY PROFILE

Rien Boom reefer transport
Specialized in reefer container transportation Europe wide

NEED

  • Delivering of reefer containers throughout Europe with own reliable and clean Euro 6 driven genset
  • Low weight and low emission
  • High payload because of heavy weight containers and maximal weight restrictions per country

SOLUTION

ECO-DRIVE genset tractor unit with 30 kVA

  • Drives 1or 2 reefer containers at the same time
  • Low weight of ECO-DRIVE (185 kg) gives Rien Boom maximum payload to transport every possible reefer which is available
carrier-supra-cng-on-road

Discover Supra units with a new package to reduce emissions.

The package comprises three key elements:

  • low emission diesel engine to reduce particulate matter by up to 50 percent versus the standard engine.
  • New R-452A refrigerant which has the same cooling capacity, fuel efficiency, reliability and refrigerant charge as the standard R-404A, but offers a 45 percent reduction in Global Warming Potential (GWP).
  • Silent option kit, which helps to reduce unit noise emissions is included in the package. To minimise noise emissions further, the “Low Emissions Pack” can be specified on the ultra-low noise, PIEK-compliant Supra City units, which operate below 60 decibels and are ideal for night-time deliveries in urban areas.

carrier-low-emissions-logo

Low emissions engine

r452a-inside-logo

Refrigerant -45% GWP

silent-city-illustration

piek-logocertified
-60 db